These device tables describe standard firmware configurations for all HIL devices. They can be viewed from the Device Configuration Table. To understand this article it is strongly recommended to first get familiar with system architecture and FPGA solver basics and principles and constraints of real-time modeling in electrical and signal processing domains.
If you find these device configurations not suitable for your application we can develop custom firmware suited to your needs.
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 2 | 0.88 | 16.0 | 3 | 6 | 0 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 4 | 0 | yes | yes | 1 | basic | 0 | no |
Configuration 2 | 3 | 0.88 | 16.0 | 3 | 6 | 0 | 16 | yes | no | yes | yes | yes | 0 | no | 0 | no | 0 | 12 | 8 | 12 | 0 | 0 | yes | yes | 1 | basic | 0 | no |
Configuration 3 | 2 | 0.88 | 16.0 | 4 | 6 | 8 | 16 | yes | yes | yes | yes | yes | 0 | no | 0 | no | 1 | 12 | 8 | 12 | 0 | 0 | yes | yes | 1 | basic | 0 | no |
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 3 | 0.64 | 16.0 | 3 | 6 | 0 | 0 | yes | no | yes | no | yes | 1 | no | 0 | no | 0 | 10 | 8 | 12 | 4 | 0 | no | no | 0 | / | 0 | no |
Configuration 2 | 4 | 0.64 | 16.0 | 3 | 6 | 0 | 0 | yes | no | yes | no | yes | 0 | no | 0 | no | 0 | 10 | 8 | 12 | 0 | 0 | no | no | 0 | / | 0 | no |
Configuration 3 | 2 | 1.28 | 16.0 | 3 | 6 | 16 | 16 | yes | no | yes | no | yes | 0 | no | 0 | no | 0 | 10 | 8 | 12 | 0 | 0 | no | no | 0 | / | 0 | no |
Configuration 4 | 2 | 0.64 | 16.0 | 4 | 6 | 16 | 16 | yes | yes | yes | yes | yes | 1 | no | 0 | no | 0 | 10 | 8 | 12 | 0 | 0 | no | no | 0 | / | 0 | no |
Configuration 5 | 2 | 0.64 | 16.0 | 3 | 6 | 0 | 0 | yes | no | yes | no | yes | 2 | no | 0 | yes | 0 | 10 | 8 | 12 | 0 | 0 | no | no | 0 | / | 0 | no |
Configuration 6 | 2 | 0.64 | 16.0 | 3 | 6 | 0 | 0 | yes | no | yes | no | yes | 1 | yes | 32 | yes | 0 | 10 | 8 | 12 | 0 | 0 | no | no | 0 | / | 0 | no |
Configuration 7 | 1 | 0.64 | 16.0 | 3 | 6 | 0 | 0 | yes | no | yes | no | yes | 1 | yes | 32 | yes | 0 | 10 | 8 | 12 | 2 | 0 | no | no | 0 | / | 0 | no |
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 3 | 1.12 | 16.0 | 3 | 6 | 0 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 4 | 0 | yes | yes | 1 | basic | 0 | no |
Configuration 2 | 4 | 1.12 | 16.0 | 3 | 6 | 0 | 16 | yes | no | yes | yes | yes | 0 | no | 0 | no | 0 | 12 | 8 | 12 | 0 | 0 | yes | yes | 1 | basic | 0 | no |
Configuration 3 | 2 | 1.12 | 16.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 0 | yes | yes | 1 | fast | 0 | no |
Configuration 4 | 3 | 1.12 | 16.0 | 3 | 6 | 0 | 0 | yes | no | yes | no | yes | 2 | no | 0 | yes | 0 | 12 | 8 | 12 | 0 | 0 | yes | yes | 1 | basic | 0 | no |
Configuration 5 | 3 | 1.12 | 16.0 | 4 | 6 | 8 | 16 | yes | yes | yes | yes | yes | 0 | no | 0 | no | 1 | 12 | 8 | 12 | 0 | 0 | yes | yes | 1 | basic | 0 | no |
Configuration 6 | 2 | 1.12 | 16.0 | 3 | 6 | 0 | 0 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 2 | 0 | yes | yes | 1 | fast | 0 | no |
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 4 | 1.12 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 4 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 2 | 6 | 1.12 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 0 | no | 0 | no | 0 | 12 | 8 | 12 | 0 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 3 | 2 | 1.12 | 64.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 2 | 12 | 8 | 12 | 0 | 3 | yes | yes | 2 | fast | 0 | no |
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 4 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 4 | 0 | yes | no | 0 | / | 0 | no |
Configuration 2 | 6 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 0 | no | 0 | no | 0 | 12 | 8 | 12 | 0 | 0 | yes | no | 0 | / | 0 | no |
Configuration 3 | 2 | 0.64 | 64.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 1 | 12 | 8 | 12 | 0 | 0 | yes | no | 0 | / | 0 | no |
Configuration 4 | 3 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 2 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 0 | yes | no | 0 | / | 0 | no |
Configuration 5 | 3 | 1.28 | 32.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 0 | yes | no | 0 | / | 0 | no |
Configuration 6 | 2 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 8 | 2 | 12 | 2 | 0 | yes | no | 0 | / | 0 | no |
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 6 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 2 | yes | 32 | yes | 0 | 12 | 8 | 12 | 4 | 3 | yes | no | 0 | / | 0 | no |
Configuration 2 | 8 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | no | 0 | / | 0 | no |
Configuration 3 | 4 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 4 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | no | 0 | / | 0 | no |
Configuration 4 | 3 | 0.64 | 64.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 2 | 12 | 8 | 12 | 0 | 3 | yes | no | 0 | / | 0 | no |
Configuration 5 | 4 | 1.28 | 32.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | no | 0 | / | 0 | no |
Configuration 6 | 5 | 0.32 | 32.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | no | 0 | / | 0 | no |
Configuration 7 | 8 | 0.64 | 16.0 | 4 | 6 | 24 | 16 | yes | yes | yes | yes | yes | 0 | no | 0 | no | 0 | 12 | 8 | 18 | 0 | 3 | yes | no | 0 | / | 0 | no |
Configuration 8 | 2 | 0.64 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 8 | 2 | 12 | 2 | 3 | yes | no | 0 | / | 0 | no |
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 6 | 1.12 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 2 | yes | 32 | yes | 0 | 12 | 8 | 12 | 4 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 2 | 8 | 1.12 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 3 | 4 | 1.12 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 4 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 4 | 3 | 1.12 | 64.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 2 | 12 | 8 | 12 | 0 | 3 | yes | yes | 2 | fast | 0 | no |
Configuration 5 | 4 | 2.24 | 32.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 6 | 5 | 0.56 | 32.0 | 4 | 6 | 32 | 16 | yes | yes | yes | yes | yes | 1 | yes | 32 | yes | 0 | 12 | 8 | 12 | 0 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 7 | 8 | 1.12 | 16.0 | 4 | 6 | 24 | 16 | yes | yes | yes | yes | yes | 0 | no | 0 | no | 0 | 12 | 8 | 18 | 0 | 3 | yes | yes | 1 | basic | 0 | no |
Configuration 8 | 1 | 1.12 | 16.0 | 3 | 6 | 32 | 16 | yes | no | yes | yes | yes | 1 | yes | 32 | yes | 0 | 8 | 2 | 12 | 2 | 3 | yes | yes | 1 | fast | 0 | no |
# of Standard processing cores (SPCs) | SPC peak processing power [GMACS] | SPC matrix memory [KWords] | Max converter weight (ideal switches) | Contactors (ideal switches) | Non-ideal switches | Time varying elements | Global GDS oversampling | Switch-level GDS oversampling | GDS switching delay | Converter power loss calculation | Converter forward voltage drop | Machine solvers | Nonlinear machine support | Nonlinear machine LUT size [KWords] | Absolute encoder protocol support | DC-DC converter solvers | Signal generators | Look Up Tables | PWM modulators | PWM analyzers | Parallel DTV detectors | Paralleling support | SFP Simulation Link support | Number of channels | Channel type | Egston SFP Link channels | ABB Proprietary protocols support | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Configuration 1 | 16 | 200.0 | 65536.0 | 6 | 16 | 64 | 16 | yes | yes | yes | yes | yes | 16 | yes | 64 | no | 16 | 16 | 16 | 32 | 4 | 3 | yes | yes | 1 | basic | 0 | no |